Perfusion index as a predictor of working pediatric caudal block under general anesthesia- A prospective observational study (2024)

  • Journal List
  • J Anaesthesiol Clin Pharmacol
  • v.38(4); Oct-Dec 2022
  • PMC9912897

As a library, NLM provides access to scientific literature. Inclusion in an NLM database does not imply endorsem*nt of, or agreement with, the contents by NLM or the National Institutes of Health.
Learn more: PMC Disclaimer | PMC Copyright Notice

Perfusion index as a predictor of working pediatric caudal block under general anesthesia- A prospective observational study (1)

HomeCurrent issueInstructionsSubmit article

J Anaesthesiol Clin Pharmacol. 2022 Oct-Dec; 38(4): 635–639.

Published online 2022 Dec 26. doi:10.4103/joacp.JOACP_34_21

PMCID: PMC9912897

PMID: 36778797

Karthika Rajan, Nandini Dave,1 Raylene Dias,2 Priyanka Muneshwar,3 Nikhil Kesarkar,4 and Vishal Saxena5

Author information Article notes Copyright and License information PMC Disclaimer

Abstract

Background and Aims:

Advances in pulse oximeter technology have enabled us to measure parameters such as perfusion index (PI). We aimed to ascertain the utility of PI in the lower limb for evaluating the onset and adequacy of the pediatric caudal block under general anesthesia. The primary objective was to monitor PI trends after caudal block. The secondary objective was to compare the role of PI, heart rate (HR), and mean arterial pressure (MAP) in detecting onset and adequacy of caudal block and to ascertain whether PI was an earlier indicator in detecting adequate block.

Material and Methods:

Twenty-five children between 1 and 6 years, who underwent general anesthesia (GA) with caudal block were included. Baseline PI, HR, and MAP were recorded prior to and post caudal block at 5, 10, 15, 20 min and on skin incision. The onset of adequate block was defined as 100% increase of PI from baseline, 15% decrease of MAP or HR from baseline. T-test was used to compare trends of PI with baseline and the number of patients who met or failed these criteria for each of these three parameters at various time intervals wasnoted.

Results:

PI increased at all time intervals in 23 of 25 patients with working caudal block (P < 0.0001). By 10 min all those with a working caudal showed a 100% increase in PI. In contrast, 15% decrease in HR was not attained until 15 min where only 8 out of 23 achieved the above criteria, reaching a maximum of 20 patients at the time of incision; a 15% decrease in MAP was observed only in one patient at 5 min, reaching a maximum of eight patients at the time of incision.

Conclusion:

PI is an earlier and more sensitive indicator of the onset of the caudal block under general anesthesia (GA) than HR and MAP.

Keywords: Caudal block, general anesthesia, heart rate, pediatric, perfusion index

Introduction

Caudal block under general anesthesia (GA) is quite popular for pediatric lower abdominal, perineal, and lower limb surgeries as it is one technique which fits all. It is relatively easy to learn with a high mean success rate[1] and a remarkable safety record.[2] However, failure of caudal block is about 4% due to abnormal anatomy, operator inexperience, and wrong choice of block.[3]

Recent advances in pulse oximeter technology have broadened the abilities to measure more parameters such as perfusion index (PI). PI is a non-invasive numerical assessment of the pulsatile strength at a monitoring site providing useful information about the peripheral perfusion status of the patient. Decrease in PI can occur because of local vasoconstriction while vasodilatation results in an increase in PI in the skin at the monitoring site.[4] Recent studies recommend that PI can be used as an early and sensitive indicator to detect the development of epidural induced sympathectomy leading to vasodilation and increased perfusion in adults,[5] but such evidence in the pediatric population is limited especially in the Indian context.

It is often very difficult to assess the quality of analgesia in children intra-operatively as most of the regional blocks are performed under general anesthesia or sedation in contrast to adults. Conventionally one waits to see the patient’s response to surgical skin incision to make a clinical decision of working caudal block. Unsuccessful block causes a rise in HR and blood pressure on skin incision due to pain.[6] This calls for a more reliable and faster objective parameter that can confirm the efficacy of caudal block in children. As demonstrated in adults whether PI can be applied to detect the onset and adequacy of the pediatric caudal block under GA remains to be elucidated. In this study, the primary outcome was to monitor PI trends after caudal block. The secondary outcome was to compare the role of PI, heart rate (HR), and mean arterial pressure (MAP) in detecting onset and adequacy of caudal block and to ascertain whether PI was an earlier indicator in detecting adequate block.

Material and Methods

This prospective observational pilot study was approved by the Institutional Ethics Committee. CTRI No: EC/OA-118/2018, Institutional Ethics Committee, Seth GS Medical College and KEM Hospital, Mumbai. The study was conducted over a period of 3 months from January 2019 to March 2019in a tertiary care teaching hospital. The sample size required was estimated from a similar study by Mohamed et al.[7] using the formula N≥2×(Zα/2+Zβ)2×SD2/(δ0) 2with the power of study as 80% to detect a difference of P value less than 0.05 and was calculated to be 25 cases. Twenty-five American Society of Anaesthesiologists (ASA) classes I and II patients between 1 and 6 years of age posted for elective lower abdominal surgery under GA with caudal block were enrolled from the pre-anesthetic clinic (PAC) a day prior to surgery. The study protocol was explained to the parents/legal guardians during the PAC and informed consent was obtained. Those who refused to consent, septic, and critically ill children on inotropes were excluded. Sampling was consecutive.

All patients were fasted as per the standard nil per oral NPO guidelines permitting clear fluids up to 2 h prior and with intravenous IV access secured in the ward. All patients received midazolam premedication 0.05 mg/kg (IV) in the preoperative holding area. On shifting to the operating room, standard monitors including electrocardiogram, non-invasive blood pressure (NIBP), pulse oximetry, end-tidal carbon dioxide, and volatile anaesthetic monitoring were instituted. NIBP cuff was attached on the arm opposite to the side of intravenous access in all the patients. The core temperature was monitored using a nasopharyngeal probe in all the patients and was maintained between 36.5 and 37.5°C. All parameters were recorded using Drager Perseus®A500 anesthesia delivery system and monitor, Dragerwerk AG and Co. Lubeck, Germany. Ringer lactate was administered as the intraoperative maintenance fluid at the rate of 6 mL/kg/h. After 3 min of preoxygenation with 100% oxygen, GA was induced with injection fentanyl 2 mg/kg and propofol 3 mg/kg IV, followed by insertion of a supraglottic airway device of appropriate size. Maintenance of anesthesia was with oxygen, air, and sevoflurane titrated to a minimum alveolar concentration MAC of 1.

Masimo Radical-7 SET® (Masimo Corporation Irvine, CA) pulse oximeter probe for monitoring PI was placed on the big toe and wrapped with gauze to reduce heat loss and to avoid the interference of ambient light. Prior to the caudal block procedure, the baseline PI was recorded, corresponding to the value at 0 min. Also, the baseline HR and MAP were recorded. The caudal block was performed by a qualified anesthesiologist with at least 3 years of experience, with the patient in the left lateral position using the landmark technique. After appreciating the definite pop during insertion of the needle and negative aspiration for blood and cerebrospinal fluid 1mL/kg of 0.125% of bupivacaine was injected at the rate of 1mL/3 s and the patients turned supine immediately. Following the caudal block, PI, HR, and MAP were recorded at 5, 10, 15, and 20 min as well as on skin incision. A working caudal block was defined as any one of the following criteria achieved, whichever occurred earlier: 100% increase of PI value from baseline, 15% decrease of MAP, or 15% decrease of HR from the baseline.[7,8]Also, the percentage of patients who met the criteria for each of these three parameters at incision was noted.

Data were analyzed using the statistical software SPSS version 24 (SPSS Inc., Chicago, IL, USA). Data were tested for normality using the Shapiro–Wilk’s test. Parametric data were expressed as mean ± standard deviation SD, while non-parametric data were expressed as numbers and percentage. Comparing PI at various time intervals with baseline was done using paired Student’s t-test where P value < 0.05was considered significant.

Results

All 25 patients provided complete data and were included in the analysis. Demographic characteristics and surgical procedures are depicted in Table 1. In 23 out of 25 patients, the PI values increased at all time intervals and werestatistically significant (P < 0.0001) [Table 2]. In the remaining two cases, the PI did not double and remained at lower values and corresponded to an increase in the HR and MAP at the time of skin incision indicating an unsuccessful block.

Table 1

Patient characteristics and surgical procedures

VariablesValues
Age (years)3.88±1.72
Weight (kg)13.68±3.31
Surgical procedures(n=25)
 Open herniotomy8
 Open orchiopexy7
 Hypospadiasis repair10

Open in a separate window

*Age, weight represented as mean±SD

Table 2

Perfusion Index (PI) at various time intervals compared to baseline

Time-pointMean±SDP
0 min1.17±0.92-
5 min3.41±1.24<0.0001
10 min4.44±1.44<0.0001
15 min5.26±1.46<0.0001
20 min5.94±1.48<0.0001
At incision6.38±1.56<0.0001

Open in a separate window

Among the 25 patients, a 100%increase in PI from the baseline was recorded in 21 patients at 5 min and in 23 patients at 10 min. So, by the first 10 min, all those with a working caudal showed a 100% increase in PI. In contrast, a 15% decrease in HR was not attained until 15 min where only 8 out of 23 achieved the above criteria, reaching a maximum of 20 patients at the time of incision. A 15% reduction in MAP was observed only in onepatient at 5,10,15 min, reaching a maximum of eightpatients at the time of incision [Figure 1]. The number of patients satisfying the definition of working caudal block at the incision is expressed in percentage showing the efficiency of PI in indicating the adequacy of the caudal block [Table 3]. There were no adverse effects related to caudal block (bloody tap, inadvertent dural puncture, bleeding at puncture site) in any of the patients.

Open in a separate window

Figure 1

Number of patients whomet the definition criteria at specific time-points for PI, HR, and MAP

Table 3

Number of cases satisfying the definition of working caudal block at incision expressed in percentage

Predefined criteriaNumber of casesPercentage
100% in PI23100
15% decrease in HR2086.95
15% decrease in MAP834.78

Open in a separate window

Discussion

Management of intraoperative pain in children remains challenging because most regional blocks are done under sedation or GA and no gold standard exists for the assessment of procedural pain. The pain intensity in children is usually assessed by physiological measures, self-report scales, and behavioral scales. The former is mainly used for measuring intraoperative analgesia. However, pain studies in children have shown that physiological measures like HR, oxygen saturation, blood pressure, or respiratory rate are neither sensitive nor specific enough.[9-11]

PI is a non-invasive numerical technique derived from a pulse oximeter signal that reflects real-time changes in peripheral perfusion. It is calculated by the ratio of infrared light absorbed by the pulsating arterial flow (AC) against the non-pulsatile signals in blood and tissues (DC) and expressed as (AC × 100/DC%).[12,13] It has a wide range from 0.02 to 20. Though various factors including peripheral vascular resistance, blood volume, and elasticity of the vascular wall can affect the peripheral PI; peripheral vascular resistance controlled by the autonomic nervous system contributes most to the changes in peripheral PI.[14,15]It was reported that the PI decrease caused by pain and other stressful stimuli was due to vasoconstriction of the peripheral arterial bed rather than the changes in the pulse pressure[16]; instead PI increase on the toe following caudal block was most likely due to sympathectomy-related vasodilatation of peripheral arterial bed and redistribution of blood volume.

In the present study, 23 cases out of 25 did attain one of the defined criteria at the time of incision indicating a successful caudal block. In these 23 cases, PI values significantly increased at all time intervals from the baseline (P < 0.0001). Umera et al.[17]conducted a similar prospective study on 40 children undergoing inguinal herniorraphy to ascertain the value of PI monitoring in predicting the success of epidural block under GA. They concluded that the PI significantly increased reflecting the vasodilatation induced by the successful block which was in accordance with our results.

We further compared the number of cases that met the predefined criteria for each of the bedside indices used for the assessment of caudal block onset. A 100% increase in PI in the 23 cases with a working caudal block was attained in the first 10 min and was sustained through to the time of incision. Comparing PI with other studied indicators, we found no significant changes in HR or MAP after the caudal block. In contrast to PI, a 15% decrease in HR or MAP was never attained in all the cases with a working caudal even at the time of incision reaching a maximum of 86.95% (20 cases out of 23) and 34.78% (8 cases out of 23), respectively. This shows that PI is able to detect the onset of successful caudal block much earlier and more consistently than either HR or MAP. It was also noted that in the two cases of failed caudal block, the PI did not double and remained at lower values and corresponded to an increase in HR and MAP at the time of skin incision.

Similar studies by Ginosar et al.[4]and Mohamed et al.[7]also showed comparable results with PI, though their comparison involved other parameters like cremasteric reflex and skin temperature gradients. The loss of cremasteric reflex has long been thought as a reliable indicator of a successful caudal block, but it only applies to male patients and it usually takes much longer to show the effects of a caudal block.[18,19] Cutaneous temperature recordings including leg-toe temperature gradient have been used as an effective indicator of sympathectomy.[20,21] But this is not always feasible due to a lack of multiple temperature probes and lack of standardization of ambient temperature.

Our study population included a hom*ogenous sample of children who were well-matched for age, type of surgery, and regional analgesia. This age group represents a vulnerable population in whom pain assessment can be challenging and there are potential risks of not treating pain adequately. As we routinely use pulse oximeter in all patients during operation, PI value is a useful objective, and non-invasive method to evaluate the effect of caudal block in pediatric patients. However, there were certain limitations to this study. Since GA itself can cause vasodilatation, it can be a confounding factor. To nullify its effect, PI values obtained from the upper extremity can be compared with those obtained from the lower extremity as caudal block affects only the lower extremity. Though this would have been ideal it was not possible in our study since there was no provision for an extra pulse oximeter probe that could detect PI. Hence as an alternative, we followed the trends of PI rather than absolute values. We did not compare the changes of skin temperature gradient in the lower limb pre- and post-caudal block with PI due to lack of temperature probes. As a directive for future research, further observations with the above-mentioned modifications can be conducted to yield robust results.

Conclusion

Our study results show that PI trends measured in the lower limb provide a more sensitive indicator for assessing the onset and efficacy of caudal block under GA than HR and MAP. Failure of increase in PI might give the anesthesiologist an early warning of the failure of caudal block, which may help to optimize the analgesia. Our results may encourage anesthesiologists to use PI instead of other traditional indicators to ensure the efficacy of pediatric caudal block.

Financial support and sponsorship

This study was supported by departmental resources.

Conflicts of interest

There are no conflicts of interest.

References

1. Schuepfer G, Konrad C, Schmeck J, Poortmans G, Staffelbach B, Jöhr M. Generating a learning curve for pediatric caudal epidural blocks: An empirical evaluation of technical skills in novice and experienced anesthetists. Reg Anesth Pain Med. 2000;25:385–8. [PubMed] [Google Scholar]

2. Gunter J. Caudal anesthesia in children: A survey. Anaesthesiology. 1991;75:A936. [Google Scholar]

3. Silvani P, Camporesi A, Agostino MR, Salvo I. Caudal anesthesia in pediatrics: An update. Minerva Anestesiol. 2006;72:453–9. [PubMed] [Google Scholar]

4. Ginosar Y, Weiniger CF, Meroz Y, Kurz V, Bdolah-Abram T, Babchenko A, et al. Pulse oximeter perfusion index as an early indicator of sympathectomy after epidural anesthesia. Acta Anaesthesiol. Scand. 2009;53:1018–26. [PubMed] [Google Scholar]

5. Wong SY, Li JY, Chen C, Tseng CH, Lion SC, Tsai SC, et al. Caudal epidural block for minor gynecologic procedures in outpatient surgery. Chang Gung Med J. 2004;27:116–21. [PubMed] [Google Scholar]

6. Baduni N, Sanwal MK, Vajifdar H, Agarwala R. Postoperative analgesia in children: A comparison of three different doses of caudal epidural morphine. J Anaesth Clinic Pharm. 2016;32:220–3. [PMC free article] [PubMed] [Google Scholar]

7. El-Sonbaty M, El-Sonbaty A. Evaluation of Perfusion index (PI) efficiency in pediatriccaudal block: Is it the time to depend on PI? Med J Cairo Univ. 2015;83:223–7. [Google Scholar]

8. Xu Z, Zhang J, Shen H, Zheng J. Assessment of pulse oximeter perfusion index in pediatric caudal block under basal ketamine anesthesia. ScientificWorldJournal. 2013;2013:183493. [PMC free article] [PubMed] [Google Scholar]

9. Appelhans BM, Luecken LJ. HR variability and pain: Associations of two interrelated homeostatic processes. Biol Psychol. 2008;77:174–82. [PubMed] [Google Scholar]

10. Julien-Marsollier F, Rachdi K, Caballero MJ, Ayanmanesh F, Vacher T, Horlin AL, et al. Evaluation of the analgesia nociception index for monitoring intraoperative analgesia in children. Br JAnaesth. 2018;121:462–8. [PubMed] [Google Scholar]

11. Sabourdin N, Peretout JB, Khalil E, Guye ML, Louvet N, Constant I. Influence of depth of hypnosis on pupillary reactivity to a standardized tetanic stimulus in patients under propofol-remifentanil target–controlled infusion: A crossover randomized pilot study. AnesthAnalg. 2018;126:70–7. [PubMed] [Google Scholar]

12. Laskowski K, Stirling A, McKay WP, Lim HJ. A systematic review of intravenous ketamine for postoperative analgesia. Can J Anaesth. 2011;58:911–23. [PubMed] [Google Scholar]

13. Allen J. Photoplethysmography and its application in clinical physiological measurement. PhysiolMeas. 2007;28:R1–39. [PubMed] [Google Scholar]

14. Reisner A, Shaltis PA, McCombie D, Asada HH. Utility of the photoplethysmogram in circulatory monitoring. Anaesthesiology. 2008;108:950–8. [PubMed] [Google Scholar]

15. Goldman JM, Petterson MT, Kopotic RJ, Barker SJ. Masimo signal extraction pulse oximetry. J Clin MonitComput. 2000;16:475–83. [PubMed] [Google Scholar]

16. Nitzan M, Babchenko A, Shemesh D, Alberton J. Influence of thoracic sympathectomy on cardiac induced oscillations in tissue blood volume. Med Biol EngComput. 2001;39:579–83. [PubMed] [Google Scholar]

17. Uemura A, Yagihara M, Miyabe M. Pulse oxymeter perfusion index as a predictor for the effect of pediatric epidural block. Anaesthesiology. 2006;105:A1354. [Google Scholar]

18. Serour F, Cohen A, Mandelberg A, Mori J, Ezra S. Dorsal penile nerve block in children under-going circumcision in a day-care surgery. Can J Anaesth. 1996;43:954–8. [PubMed] [Google Scholar]

19. Yang C, Song B, Tan J, Liu X, Wei GH. Testicular torsion in children: A 20-year retrospective study in a single institution. ScientificWorldJournal. 2011;11:362–8. [PMC free article] [PubMed] [Google Scholar]

20. Stevens MF, Werdehausen R, Hermanns H, Lipfert P. Skin temperature during regional anesthesia of the lower extremity. AnesthAnalg. 2006;102:1247–51. [PubMed] [Google Scholar]

21. Frank SM, Shir Y, Raja SN, Fleisher LA, Beattie C. Core hypothermia and skin-surface temperature gradients. Epidural versus general anesthesia and the effects of age. Anaesthesiology. 1994;80:502–8. [PubMed] [Google Scholar]

Articles from Journal of Anaesthesiology, Clinical Pharmacology are provided here courtesy of Wolters Kluwer -- Medknow Publications

Perfusion index as a predictor of working pediatric caudal block under general anesthesia- A prospective observational study (2024)

FAQs

What is the perfusion index for pediatric patients? ›

PI is a parameter which is calculated as the ratio (AC/DC × 100) of pulsatile arterial blood flow (AC) to non-pulsatile (static) blood flow (DC) in peripheral tissues measured by pulse oximeter. It gives values from 0.02 to 20. Its normal average value is 1.4.

What does perfusion index indicate? ›

Perfusion index (PI) is defined as the ratio of pulsatile blood flow to non-pulsatile blood flow in a patient's peripheral tissue, such as in a fingertip, toe, or ear lobe. It is measured using a pulse oximeter depending on the differential absorption of infrared light [10].

What is perfusion index an assessment of? ›

Perfusion index: This ratio shows how much blood is flowing through an area. The higher the number, the better blood can flow through. Lower numbers can signal health problems with your heart or blood vessels.

What are the determinants of perfusion index? ›

PI determinants are complex and interlinked, involving and reflecting the interaction between peripheral and central haemodynamic characteristics, such as vascular tone and stroke volume.

Is 3 a good perfusion index? ›

Low perfusion index includes scores 0–5; high perfusion index includes scores >5.

What are pediatric signs of poor perfusion? ›

Infants have sluggish capillary refill and poor peripheral perfusion. Acute hemorrhagic anemia due to acute blood loss can present with symptoms of hypovolemia including poor perfusion, hypotension, tachycardia, and pallor. A decrease in peripheral perfusion occurs with a 10% loss of blood volume.

What is the normal pi range by age? ›

Normal values vary with age; in term neonates median PI was 1.7 (interquartile range 1.18–2.5), in adults varying from 0.3–10 [3, 6]. Understandably, warm shock would have higher PI whereas cold shock, a low PI.

What is a bad perfusion index? ›

The peripheral perfusion index (PI) is derived from the photoelectric plesthysmographic signal of pulse oximetry and has been shown to reflect changes in peripheral perfusion [3,4]. A PI value of 1.4 indicates the presence of poor peripheral perfusion in critically ill patients [3].

Is a 10% perfusion index good? ›

The normal perfusion index (PI) ranges from 0.02% to 20%. If the perfusion index is at or below 0.4% showing weak pulse strength, then the oximeter reading can be unreliable.

Is pi related to blood pressure? ›

[2,3,4] The value of PI is inversely related to the vascular tone, though not in a linear fashion. Therefore, vasodilatation reflecting higher baseline PI has been associated with reductions in blood pressure (BP) following spinal anaesthesia.

What does poor perfusion mean? ›

Poor perfusion is defined as inadequate circulation of blood through organs and tissues manifested by vital sign abnormalities and/or signs and symptoms of organ dysfunction. 4. Base hospital contact should be initiated on patients who are hypotensive and/or those who have poor perfusion.

Which finger is best for a pulse oximeter? ›

Choosing the Right Finger

When it comes to choosing the finger for pulse oximeter readings, the general consensus is that the middle finger or the index finger provides the most accurate results. These fingers are typically preferred due to their adequate blood flow and the thickness of the skin in the fingertip area.

What are the signs of good organ perfusion? ›

Either systolic or mean arterial pressure can be used to determine adequacy of pressure, although a mean arterial pressure of greater than 70 mmHg is considered a more accurate description of normal tissue perfusion.

When will you see signs of poor tissue perfusion? ›

Tissue perfusion is usually decreased when the gums are pale, rather than pink, sometimes when very pink, and the capillary refill time (CRT) exceeds 1.5 seconds, or the mean arterial pressure (MAP) is less than 60 mmHg.

What happens if perfusion index is high? ›

PI is calculated by dividing the pulsatile signal (AC) by the nonpulsatile signal (DC) times 100, and is expressed as a percent ranging from 0.02% to 20%. A higher PI value, therefore, indicates a stronger pulsatile signal and better peripheral circulation at the sensor site.

What is a normal cerebral perfusion pressure for a child? ›

CPP-B = between 30 and 40 mm Hg for 0- to 5-yr olds, between 35 and 50 mm Hg for 6- to 11-yr olds, and between 50 and 60 mm Hg for 12-yr olds and older.

How do you assess perfusion in children? ›

The child has to be supine. Raise the leg up slightly, blanch the bottom of the foot, and look for that capillary refill time. Again, it should be less than 2 seconds. If it's greater than that, we may have some perfusion issues.

Is a perfusion index of 1.2 good? ›

The normal perfusion index (PI) ranges from 0.02% to 20%. If the perfusion index is at or below 0.4% showing weak pulse strength, then the oximeter reading can be unreliable. Peripheral artery diseases, diabetes, obesity, blood clots, etc. are the reasons for poor perfusion.

Top Articles
Latest Posts
Article information

Author: Rev. Leonie Wyman

Last Updated:

Views: 6306

Rating: 4.9 / 5 (79 voted)

Reviews: 94% of readers found this page helpful

Author information

Name: Rev. Leonie Wyman

Birthday: 1993-07-01

Address: Suite 763 6272 Lang Bypass, New Xochitlport, VT 72704-3308

Phone: +22014484519944

Job: Banking Officer

Hobby: Sailing, Gaming, Basketball, Calligraphy, Mycology, Astronomy, Juggling

Introduction: My name is Rev. Leonie Wyman, I am a colorful, tasty, splendid, fair, witty, gorgeous, splendid person who loves writing and wants to share my knowledge and understanding with you.